ganzo wrote:
MammaGutt wrote:
Remove the old one.
Insert the new one.
Hot-pluggable and fully redundant given that you have connected both power supplies in the cage.
Hi MammaGutt,
Thank you for your reply.
So that means no need to take actions like enter service mode via cli. Is it correct?
Just switch off and remove defected one and insert new one and switch on. Right?
Correct. If you want to be by the book, you could enable maintenance mode, but that will only prevent call home events. If you have call home, you might miss other actual events, so I would just pull it.