Hi all,

We have had a node fail in our 8200. It was completely dead with no lights. We have had this replaced at the new node seems to have the 2 ports configured for RCFC missing. The node is part of the cluster and is passing traffic (other than RCFC).

When you run showport they are completely missing.

I was wondering if anyone had any thoughts please? How can we get the system to see these ports again?

Thank You
MammaGutt
Posts: 1578
Joined: Mon Sep 21, 2015 2:11 pm
Location: Europe

Re: RCFC NetworkInterfaces Missing After Node Replacement

Post by MammaGutt »

I would do "showport" in CLI and if they are there....

Not sure who replaced the node and where it came from, but if you're missing 2 ports it could be the onboard FC HBA that's dead.